The Aqua TROLL 500 is a fully customizable multiparameter sonde with interchangeable sensors and a smartphone interface that delivers accurate data and enables simplified calibration, panoramic data view and report creation. Ideal for spot-checking and profiling applications when used with a Wireless TROLL Com or long-term monitoring with VuLink.
The Aqua TROLL 500 offers the flexibility, reliability and ruggedness you need for spot checking, low-flow sampling, remote monitoring, and long-term water or stormwater monitoring. Corrosion-resistant titainum construction stands up to harsh environments, and a convenient LCD readout of sensor health and connectivity gives you confidence in your deployment.
The customizable Aqua TROLL 500 sonde comes with sensors that include:
- RDO® Optical Dissolved Oxygen
- Actual and specific conductivity
- pH/ORP
- Salinity
- Total dissolved solids (TDS).
- Resistivity
- Density
- Turbidity
- Temperature and pressure
- Ion Selective Electrodes
- Fluorometers
Connect the Aqua TROLL 500 to a Wireless TROLL Com and use it as a handheld, or connect the sonde to control systems or telemetry for remote monitoring.
BE SMART with Aqua TROLL 500
• Lower cost of ownership: Rugged multiparameter sonde with wet-mateable sensors replaces single parameter instruments and requires minimal maintenance and calibration.
• Data you can count on: The corrosion-resistant multiparameter sonde withstands harsh environments. Highly stable sensors with simple calibration. LCD readout of sensor health and connectivity gives you confidence in your deployment.
• Simple setup: Connect easily with telemetry, PLC/SCADA or dataloggers, or download real-time data wirelessly via mobile app for spot checks and profiling. The app walks you through instrument setup, just click to download and share data— no training or post-processing required.
BE MOBILE with Aqua TROLL 500
• Save time in the field: Auto-configuration and fast sensor response speed up sampling, while automated data collection eliminates the need to record data in field logs.
• Use the Aqua TROLL 500 anywhere: Flexible multiparameter sonde works for spot checks and low-flow sampling as well as long-term deployments. Anti-fouling wiper and titanium construction provide reliability even in challenging conditions.
• Take your data with you: VuSitu Mobile App records data directly from the probe. Log Setup Assistant simplifies instrument setup and reduces errors. Optimize your data with Panoramic Live Data.
Aqua TROLL 500 Applications:
- SURFACE WATER SPOT SAMPLING AND PROFILING
- REMOTE MONITORING VIA TELEMETRY
- LONG-TERM DRINKING WATER, WASTEWATER OR STORMWATER MONITORING
- AQUACULTURE
- WIRED OR WIRELESS WATER QUALITY NETWORKS
Aqua TROLL 500 Specifications
- OPERATING TEMP. (Non-Freezing) -5 to 50° C (23 to 122° F) ISE: Ammonium and Nitrate 0 - 40°C, Chloride 0 - 50°C
- STORAGE TEMP. Components Without Fluid -40°C to + 65°C (Non Freezing Water) pH/ORP Sensors -5°C to +65°C Ammonium/Nitrate: 0 - 40°C Chloride: 0 - 50°C
- DIMENSIONS: Length: 46 cm (18.145”) (includes connector). With bail: 59 cm (23.25”) Diameter: 4.7 cm (1.860”)
- WEIGHT: 0.978 kg / 2.15 lbs. (includes instrument, sensors, restrictor and bumpers)
- WETTED MATERIALS (SONDE AND SENSORS) PC, PC alloy, Delrin, Santoprene, Inconel, Viton, Titanium, Platinum, Ceramic, Nylon, PVC, Graphite
- SENSOR HEX SCREW DRIVER 0.050, 1.3 mm
- ENVIRONMENTAL RATING IP68 with all sensors and cable attached IP67 without the sensors or cable attached
- MAX. PRESSURE RATING Up to 150 PSI Ammonium/Nitrate up to 30PSI
- OUTPUT OPTIONS RS-485/MODBUS, SDI-12, Bluetooth
- EXTERNAL POWER VOLTAGE 8-36 VDC; Required for normal operation
- EXTERNAL POWER CURRENT Sleep: < 0.2 mA typical; Measurement: 40 mA typical, 75 mA Max
- INTERNAL MEMORY AND DATA LOGGING Use external datalogger or telemetry
- PROBE READING RATES 1 reading every 2 seconds
- COMMUNICATION DEVICE Wireless TROLL Com
- CABLE OPTIONS Vented or non-vented polyurethane or vented Tefzel®
- LCD DISPLAY Integrated display shows status of sonde, sensor ports, power voltage and connectivity, enable/disable BT.
- SOFTWARE Android: VuSitu through Google Play Windows: Win-Situ 5 Data Services: HydroVu
- INTERFACE Android 4.4, requires BlueTooth 2.0
- CERTIFICATIONS CE, FCC, WEEE, RoHS Compliant
Standard Sensors for Aqua TROLL 500
TEMPERATURE*
- Accuracy - ±0.1° C
- Range - -5 to 50° C (23 to 122° F)
- Resolution - 0.01° C
- Response Time - T63<2s, T90<15s, T95<30s
- Units of Measure - Celsius, Fahrenheit
- Methodology - EPA 170.1
BAROMETRIC PRESSURE (VENTED MODELS ONLY)
- Accuracy - +/- 1.0
- Range - mBars 300 - 1100 mBars
- Resolution - 0.1 mBar
- Response Time - T63<1s, T90<1s, T95<1s
- Units of Measure - Pressure: psi, kPa, bar, mbar, inHg, mmHg;
- Methodology - Silicon strain gauge
pH
- Accuracy - ±0.1 pH unit or better
- Range - 0 to 14 pH units
- Resolution - 0.01 pH unit
- Response Time - T63<3s, T90<15s, T95<30s
- Units of Measure - pH units, mV Std.
- Methodology - Methods 4500-H+ EPA 150.2
ORP
- Accuracy - +/- 5 mV
- Range - ±1400 mV
- Resolution - 0.1 mV
- Response Times - T63<3s, T90<15s, T95<30s
- Units of Measure - mV
- Methodology - Std. Methods 2580
CONDUCTIVITY
- Accuracy - ±0.5% of reading plus 1 µS/ cm from 0 to 100,000 µS/ cm; ±1.0% of reading from 100,000 to 200,000 µS/ cm; ±2.0% of reading from 200,000 to 350,000 µS/cm
- Range - 0 to 350,000 μS/cm; TDS 0-350 ppt; Salinity 0-350 PSU
- Resolution - 0.1 μS/cm; TDE 0.1 ppt; Salinity 0.1 PSU
- Response Times - T63<1s, T90<3s, T95<5s
- Units of Measure - Actual conductivity (μS/cm, mS/ cm); Specific conductivity (μS/ cm, mS/cm) Salinity (PSU, ppt); Total dissolved solids (ppt, ppm); Resistivity (Ohms-cm); Density (g/cm3)
- Methodology - Std. Methods 2510, EPA 120.1 Std. Methods 2520A
RUGGED DISSOLVED OXYGEN (RDO) WITH RDO-X OR FAST CAP
- Accuracy - ±0.1mg/L +/-2% of reading
- Range - 0 to 20 mg/L, 0 to 60 mg/L
- Resolution - 0.01 mg/L
- Response Times - RDO-X: T63<15s, T90<45s, T95<60s Fast Cap: T63<1s, T90<15s, T95<30s mg/L
- Units of Measure - %saturation, ppm
- Methodology - EPA-approved In-Situ Methods: 1002-8- 2009, 1003-8-2009, 1004-8-2009
TURBIDITY - TSS (TOTAL SUSPENDED SOLIDS)
- Accuracy - +/-2% of reading or +/-2 NTU, FNU, w.i.g.
- Range - 0 – 4,000 NTU, 0-1,500 mg/L
- Resolution - 0.01 NTU (0- 1,000); 0.1 NTU (1,000-4,000) 0.1 mg/L
- Response Times - T63<1s, T90<1s, T95<1s
- Units of Measure - NTU, FNU ppt, mg/L
- Methodology - ISO 7027
AMMONIUM (NH4+ - N) RATED TO 25 M DEPTH -Unionized Ammonia, Total Ammonia (requires salinity, temperature and pH)
- Accuracy - ±10% or ± 2 mg/L, w.i.g. (freshwater only)
- Range - 0-10,000 mg/L as N
- Resolution - 0.01 mg/L
- Response Times - T63<1s, T90<10s, T95<30s
- Units of Measure - mg/L, ppm, mV
- Methodology - N/A
NITRATE (NO3 - - N) RATED TO 25 m DEPTH
- Accuracy - ±10% or ± 2 mg/L, w.i.g. (freshwater only)
- Range - 0-40,000 mg/L as N
- Resolution - 0.01 mg/L
- Response Times - T63<1s, T90<1s, T95<1s
- Units of Measure - mg/L, ppm, mV
- Methodology -Std. Methods 4500- NO3 D
CHLORIDE (CL- -)
- Accuracy - ±10% or ± 2 mg/L, w.i.g.12 (freshwater only)
- Range - 0-150,000 mg/L
- Resolution - 0.01 mg/L
- Response Times - T63<1s, T90<10s, T95<30s
- Units of Measure - mg/L, ppm, mV
- Methodology -Std. Methods 4500- Cl- D
PRESSURE (OPTIONAL)
- Accuracy - ±0.1% FS from -5 to 50°C
- Range - Non-Vented or Vented 9.0 m (30 ft.) - Burst: 27 m (90 ft.) 30 m (100 ft.) - Burst: 40 m (130 ft.) 76 m (250 ft.) - Burst: 107 m (350 ft.) 100 m (325 ft.) - Burst: 200 m (650 ft.)
- Resolution - 0.01% full scale
- Response Times - T63<1s, T90<1s, T95<1s
- Units of Measure - Pressure: psi, kPa, bar, mbar, inHg, mmHg; Level: in, ft., mm, cm, m; Level: in, ft., mm, cm, m
- Methodology - Piezoresistive; Ceramic
WARRANTY
2 year - Sonde, RDO and sensor cap, temperature/conductivity, temperature only, turbidity (excluding pH/ORP); 1 year - pH/ORP, chloride ISE, accessories 90 Days - Nitrate and Ammonium ISE sensors; See warranty policy (www.in-situ.com/warranty)