The Aqua TROLL 500 is a fully customizable multiparameter sonde with interchangeable sensors and a smartphone interface that delivers accurate data and enables simplified calibration, panoramic data view and report creation. Ideal for spot-checking and profiling applications when used with a Wireless TROLL Com or long-term monitoring with VuLink.

The Aqua TROLL 500 offers the flexibility, reliability and ruggedness you need for spot checking, low-flow sampling, remote monitoring, and long-term water or stormwater monitoring. Corrosion-resistant titainum construction stands up to harsh environments, and a convenient LCD readout of sensor health and connectivity gives you confidence in your deployment.

The customizable sonde comes with sensors that include:

• RDO® Optical Dissolved Oxygen

• Actual and specific conductivity

• pH/ORP

• Salinity

• Total dissolved solids (TDS).

 • Resistivity

• Density

• Turbidity

• Temperature and pressure

• Ion Selective Electrodes

• Fluorometers

Connect the Aqua TROLL 500 to a Wireless TROLL Com and use it as a handheld, or connect the sonde to control systems or telemetry for remote monitoring.

BE SMART

• Lower cost of ownership: Rugged multiparameter sonde with wet-mateable sensors replaces single parameter instruments and requires minimal maintenance and calibration.

• Data you can count on: The corrosion-resistant multiparameter sonde withstands harsh environments. Highly stable sensors with simple calibration. LCD readout of sensor health and connectivity gives you confidence in your deployment.

• Simple setup: Connect easily with telemetry, PLC/SCADA or dataloggers, or download real-time data wirelessly via mobile app for spot checks and profiling. The app walks you through instrument setup, just click to download and share data— no training or post-processing required.

BE MOBILE

• Save time in the field: Auto-configuration and fast sensor response speed up sampling, while automated data collection eliminates the need to record data in field logs.

• Use the Aqua TROLL 500 anywhere: Flexible multiparameter sonde works for spot checks and low-flow sampling as well as long-term deployments. Anti-fouling wiper and titanium construction provide reliability even in challenging conditions.

• Take your data with you: VuSitu Mobile App records data directly from the probe. Log Setup Assistant simplifies instrument setup and reduces errors. Optimize your data with Panoramic Live Data.  

Applications:

• SURFACE WATER SPOT SAMPLING AND PROFILING

• REMOTE MONITORING VIA TELEMETRY

• LONG-TERM DRINKING WATER, WASTEWATER OR STORMWATER MONITORING

• AQUACULTURE

• WIRED OR WIRELESS WATER QUALITY NETWORKS   

Specifications

OPERATING TEMP. (Non-Freezing) -5 to 50° C (23 to 122° F) ISE: Ammonium and Nitrate 0 - 40°C, Chloride 0 - 50°C

STORAGE TEMP. Components Without Fluid -40°C to + 65°C (Non Freezing Water) pH/ORP Sensors -5°C to +65°C Ammonium/Nitrate: 0 - 40°C Chloride: 0 - 50°C 

DIMENSIONS: Length: 46 cm (18.145”) (includes connector). With bail: 59 cm (23.25”)  Diameter: 4.7 cm (1.860”)

WEIGHT: 0.978 kg / 2.15 lbs. (includes instrument, sensors, restrictor and bumpers)

WETTED MATERIALS (SONDE AND SENSORS) PC, PC alloy, Delrin, Santoprene, Inconel, Viton, Titanium, Platinum, Ceramic, Nylon, PVC, Graphite

SENSOR HEX SCREW DRIVER 0.050, 1.3 mm

ENVIRONMENTAL RATING IP68 with all sensors and cable attached IP67 without the sensors or cable attached

MAX. PRESSURE RATING Up to 150 PSI Ammonium/Nitrate up to 30PSI

OUTPUT OPTIONS RS-485/MODBUS, SDI-12, Bluetooth

EXTERNAL POWER VOLTAGE 8-36 VDC; Required for normal operation

EXTERNAL POWER CURRENT Sleep: < 0.2 mA typical; Measurement: 40 mA typical, 75 mA Max

INTERNAL MEMORY AND DATA LOGGING Use external datalogger or telemetry

PROBE READING RATES 1 reading every 2 seconds

COMMUNICATION DEVICE Wireless TROLL Com

CABLE OPTIONS Vented or non-vented polyurethane or vented Tefzel®

LCD DISPLAY Integrated display shows status of sonde, sensor ports, power voltage and connectivity, enable/disable BT.

SOFTWARE Android: VuSitu through Google Play Windows: Win-Situ 5 Data Services: HydroVu

INTERFACE Android 4.4, requires BlueTooth 2.0

CERTIFICATIONS CE, FCC, WEEE, RoHS Compliant

 

Standard Sensors

TEMPERATURE*

Accuracy - ±0.1° C

Range - -5 to 50° C (23 to 122° F)

Resolution - 0.01° C

Response Time -  T63<2s, T90<15s, T95<30s

Units of Measure - Celsius, Fahrenheit

Methodology - EPA 170.1

BAROMETRIC PRESSURE (VENTED MODELS ONLY)

Accuracy - +/- 1.0

Range - mBars 300 - 1100 mBars

Resolution - 0.1 mBar

Response Time - T63<1s, T90<1s, T95<1s

Units of Measure - Pressure: psi, kPa, bar, mbar, inHg, mmHg;

Methodology - Silicon strain gauge

pH

Accuracy - ±0.1 pH unit or better

Range - 0 to 14 pH units

Resolution - 0.01 pH unit

Response Time - T63<3s, T90<15s, T95<30s

Units of Measure - pH units, mV Std.

Methodology - Methods 4500-H+ EPA 150.2

ORP

Accuracy - +/- 5 mV

Range - ±1400 mV

Resolution - 0.1 mV

Response Times - T63<3s, T90<15s, T95<30s

Units of Measure - mV

Methodology - Std. Methods 2580

 

CONDUCTIVITY

Accuracy - ±0.5% of reading plus 1 µS/ cm from 0 to 100,000 µS/ cm;  ±1.0% of reading from 100,000 to 200,000 µS/ cm; ±2.0% of reading from 200,000 to 350,000 µS/cm

Range - 0 to 350,000 μS/cm; TDS 0-350 ppt; Salinity 0-350 PSU

Resolution - 0.1 μS/cm; TDE 0.1 ppt; Salinity 0.1 PSU

Response Times - T63<1s, T90<3s, T95<5s

Units of Measure - Actual conductivity (μS/cm, mS/ cm); Specific conductivity (μS/ cm, mS/cm) Salinity (PSU, ppt); Total dissolved solids (ppt, ppm); Resistivity (Ohms-cm); Density (g/cm3)

Methodology - Std. Methods 2510, EPA 120.1 Std. Methods 2520A

RUGGED DISSOLVED OXYGEN (RDO) WITH RDO-X OR FAST CAP

Accuracy - ±0.1mg/L +/-2% of reading

Range - 0 to 20 mg/L, 0 to 60 mg/L 

Resolution - 0.01 mg/L

Response Times - RDO-X: T63<15s, T90<45s, T95<60s Fast Cap: T63<1s, T90<15s, T95<30s mg/L

Units of Measure - %saturation, ppm

Methodology - EPA-approved In-Situ Methods: 1002-8- 2009, 1003-8-2009, 1004-8-2009

TURBIDITY - TSS (TOTAL SUSPENDED SOLIDS)

Accuracy - +/-2% of reading or +/-2 NTU, FNU, w.i.g.

Range - 0 – 4,000 NTU, 0-1,500 mg/L

Resolution - 0.01 NTU (0- 1,000); 0.1 NTU (1,000-4,000) 0.1 mg/L

Response Times - T63<1s, T90<1s, T95<1s

Units of Measure - NTU, FNU ppt, mg/L

Methodology - ISO 7027

AMMONIUM (NH4+ - N) RATED TO 25 M DEPTH -Unionized Ammonia, Total Ammonia (requires salinity, temperature and pH)

Accuracy - ±10% or ± 2 mg/L, w.i.g. (freshwater only)

Range -  0-10,000 mg/L as N

Resolution -  0.01 mg/L 

Response Times - T63<1s, T90<10s, T95<30s

Units of Measure - mg/L, ppm, mV

Methodology -  N/A    

NITRATE (NO3 - - N) RATED TO 25 m DEPTH

Accuracy - ±10% or ± 2 mg/L, w.i.g. (freshwater only)

Range - 0-40,000 mg/L as N

Resolution - 0.01 mg/L

Response Times - T63<1s, T90<1s, T95<1s 

Units of Measure - mg/L, ppm, mV

Methodology -Std. Methods 4500- NO3 D

CHLORIDE (CL- -)

Accuracy - ±10% or ± 2 mg/L, w.i.g.12 (freshwater only)

Range - 0-150,000 mg/L 

Resolution - 0.01 mg/L

Response Times - T63<1s, T90<10s, T95<30s

Units of Measure - mg/L, ppm, mV

Methodology -Std. Methods 4500- Cl- D

PRESSURE (OPTIONAL)

Accuracy - ±0.1% FS from -5 to 50°C

Range - Non-Vented or Vented 9.0 m (30 ft.) - Burst: 27 m (90 ft.) 30 m (100 ft.) - Burst: 40 m (130 ft.) 76 m (250 ft.) - Burst: 107 m (350 ft.) 100 m (325 ft.) - Burst: 200 m (650 ft.) 

Resolution - 0.01% full scale

Response Times - T63<1s, T90<1s, T95<1s 

Units of Measure - Pressure: psi, kPa, bar, mbar, inHg, mmHg; Level: in, ft., mm, cm, m; Level: in, ft., mm, cm, m

Methodology - Piezoresistive; Ceramic

WARRANTY

2 year - Sonde, RDO and sensor cap, temperature/conductivity, temperature only, turbidity (excluding pH/ORP); 1 year - pH/ORP, chloride ISE, accessories 90 Days - Nitrate and Ammonium ISE sensors; See warranty policy (www.in-situ.com/warranty)