Now Selling Draeger Gas Detection & Respiratory Products
Now Selling Draeger Gas Detection & Respiratory Products
Cart 0
Horiba LAQUAtwin Pocket Meters
Horiba LAQUAtwin Pocket Meters
Horiba LAQUAtwin Pocket Meters
Horiba LAQUAtwin Pocket Meters
Horiba Instruments

Horiba LAQUAtwin Pocket Meters

Regular price $99.00 Unit price per
Shipping calculated at checkout.

Horiba LAQUAtwin Pocket Meters

Your lab-in-a-pocket. Available for pH, Conductivity, Salt, Sodium-Ion, Potassium-Ion, Nitrate-Ion or Calcium-Ion.

HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.

Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.

  • Auto calibration
  • Auto temperature compensation
  • Auto stable / auto hold measurement
  • Auto power off: 30 mins
  • Low battery indicator
  • IP67 Rating dust & waterproof
  • Replaceable sensor
  • 400 Hours battery life: continuous use without backlight
  • Material: ABS epoxy 
  • Display: custom (monochrome) LCD with backlight
  • Operating conditions: 5 to 40°C, 85% or less relative humidity
  • Warranty: 2 years - meter; 6 months - sensor
  • Packed in handy carrying case

Models & Specifications

pH-11

  • Glass Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.1ml (0.05ml with sampling sheet B)
  • pH Range / Resolution: 0.0 to 14.0 pH / 0.1 pH
  • Accuracy: +/- 0.1 pH
  • pH Calibration Curves: USA - 1.68, 4.01, 7.00, 10.01 & 12.46. NIST - 1.68, 4.01, 6.86, 9.18 & 12.46
  • mV Range / Resolution: +/- 650 mV / 1 mV
  • No Temperature Display

Includes: 4.01 & 7.00 pH buffers (14 mL each), batteries, dropper, manuals & case

pH-22

  • Glass Electrode
  • 3 Calibration Points
  • Minimum sample volume: 0.1ml (0.05ml with sampling sheet B)
  • pH Range / Resolution: 0.00 to 14.00 pH / 0.01 pH
  • Accuracy: +/- 0.01 pH
  • pH Calibration Curves: USA - 1.68, 4.01, 7.00, 10.01 & 12.46. NIST - 1.68, 4.01, 6.86, 9.18 & 12.46
  • mV Range / Resolution: +/- 650 mV / 1 mV
  • No Temperature Display

Includes: 4.01 & 7.00 pH buffers (14 mL each), batteries, dropper, manuals & case

pH-33

  • Glass Electrode
  • 5 Calibration Points
  • Minimum sample volume: 0.1ml (0.05ml with sampling sheet B)
  • pH Range / Resolution: 0.00 to 14.00 pH / 0.01 pH
  • Accuracy: +/- 0.01 pH
  • pH Calibration Curves: USA - 1.68, 4.01, 7.00, 10.01 & 12.46. NIST - 1.68, 4.01, 6.86, 9.18 & 12.46
  • mV Range / Resolution: +/- 650 mV / 1 mV
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 4.01 & 7.00 pH buffers (14 mL each), batteries, dropper, manuals & case

EC-11 (Conductivity)

  • 2 Electrode Bipolar AC
  • 2 Calibration Points
  • Minimum sample volume: 0.12mL
  • Conductivity Range / Resolution: 0 to 199 uS/cm / 1 uS/cm, 200 to 1999 uS/cm / 1 uS/cm, 2.00 to 19.99 mS/cm / 0.01 mS/cm
  • Accuracy: +/- 2% Full Scale (for each range)
  • Calibration Curves: 1413 uS/cm, 12.88 mS/cm
  • No Temperature Display

Includes: 1413 uS/cm & 12.88 uS/cm Conductivity Standard Solutions (14 mL each), conditioning solution (4 mL), batteries, dropper, manuals & case

EC-22 (Conductivity)

  • 2 Electrode Bipolar AC
  • 3 Calibration Points
  • Minimum sample volume: 0.12mL
  • Conductivity Range / Resolution: 0 to 199 uS/cm / 1 uS/cm, 200 to 1999 uS/cm / 1 uS/cm, 2.00 to 19.99 mS/cm / 0.01 mS/cm, 20.0 to 199.9 mS/cm / 0.1 mS/cm
  • Accuracy: +/- 2% Full Scale (0 to 19.99 mS/cm), +/- 5% FS (20.0 to 199.9 mS/cm)
  • Calibration Curves: 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 1413 uS/cm & 12.88 uS/cm Conductivity Standard Solutions (14 mL each), conditioning solution (4 mL), batteries, dropper, manuals & case

EC-33 (Conductivity)

  • 2 Electrode Bipolar AC
  • 3 Calibration Points
  • Minimum sample volume: 0.12mL
  • Conductivity Range / Resolution: 0 to 199 uS/cm / 1 uS/cm, 200 to 1999 uS/cm / 1 uS/cm, 2.00 to 19.99 mS/cm / 0.01 mS/cm, 20.0 to 199.9 mS/cm / 0.1 mS/cm
  • TDS Range / Resolution: 0.0 to 99.9 ppm / 0.1 ppm, 100 to 999 ppm / 1 ppm, 1000 to 9990 ppm / 10 ppm
  • Accuracy: +/- 2% Full Scale (0 to 19.99 mS/cm), +/- 5% FS (20.0 to 199.9 mS/cm)
  • Calibration Curves: Conductiviity - 1413 uS/cm, 12.88 mS/cm, 111.8 mS/cm, TDS - TDS Factor (0.4 to 1.0) / EN 27888 / 442 / NaCL 
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 1413 uS/cm & 12.88 uS/cm Conductivity Standard Solutions (14 mL each), conditioning solution (4 mL), batteries, dropper, manuals & case

Salt-11

  • 2 Electrode Bipolar AC
  • 2 Calibration Points
  • Minimum sample volume: 0.12mL
  • Salt Range / Resolution: 0.0 to 100.0 g/L / 0.1 g/L, 0.00 to 10.00% / 0.1%
  • Accuracy: +/- 2% Full Scale (0.0 to 9.9 g/L), +/- 4% FS (10.0 to 100.0 g/L)
  • Calibration Curves: NaCL / Sea water
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 0.5% & 5.0% NaCL Standard Solutions (14 mL each), conditioning solution (4 mL), batteries, dropper, manuals & case

Salt-22

  • Ion Selective Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.3mL (0.05mL with sampling sheet B)
  • Salinity Range: 0.01 to 25% by weight
  • Resolution: 0.00 to 0.99% / 0.01%, 1.0 to 9.9% / 0.1%, 10 to 25% / 1%
  • Accuracy: +/- 10% or reading value
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 0.5% & 5.0% NaCL Standard Solutions (14 mL each), conditioning solution (4 mL), batteries, dropper, manuals & case

Na-11 (Sodium Ion)

  • Ion Selective Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.3mL (0.05mL with sampling sheet B)
  • Range: 2 to 9900 ppm (mg/L) (0.1 to 430 mmol/L)
  • Resolution: 0 to 99 ppm - 1 ppm, 100 to 990 ppm - 10 ppm, 1000 to 9900 ppm - 100 ppm
  • Accuracy: +/- 10% of actual value
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 150 & 2000 ppm Standard Solution (14 mL each), Sampling Sheet B (5 pieces), batteries, dropper, manuals & case

K-11 (Potassium Ion)

  • Ion Selective Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.3mL (0.05mL with sampling sheet B)
  • Range: 4 to 9900 ppm (mg/L) (0.1 to 430 mmol/L), 2 to 5000 kg/10a (soil/water ratio 1:5)
  • Resolution: 0 to 99 ppm - 1 ppm, 100 to 990 ppm - 10 ppm, 1000 to 9900 ppm - 100 ppm
  • Accuracy: +/- 10% of actual value
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 150 & 2000 ppm Standard Solution (14 mL each), Sampling Sheet B (5 pieces), batteries, dropper, manuals & case

NO3-11 (Nitrate Ion)

  • Ion Selective Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.3mL (0.05mL with sampling sheet B)
  • Range: NO3 - 6 to 9900 ppm (mg/L) (0.1 to 160 mmol/L), NO3-N - 1.4 to 2200 ppm (mg/L)
  • Resolution: 0 to 99 ppm - 1 ppm, 100 to 990 ppm - 10 ppm, 1000 to 9900 ppm - 100 ppm
  • Accuracy: +/- 10% of actual value
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 150 & 2000 ppm Standard Solution (14 mL each), Sampling Sheet B (5 pieces), batteries, dropper, manuals & case

Ca-11 (Calcium Ion)

  • Ion Selective Electrode
  • 2 Calibration Points
  • Minimum sample volume: 0.3mL (0.05mL with sampling sheet B)
  • Range: 4 to 9900 ppm (mg/L) (0.1 to 250 mmol/L)
  • Resolution: 0 to 99 ppm - 1 ppm, 100 to 990 ppm - 10 ppm, 1000 to 9900 ppm - 100 ppm
  • Accuracy: +/- 20% of actual value
  • Temperature Display / Resolution: 0 to 50.0° C / 0.1° C

Includes: 150 & 2000 ppm Standard Solution (14 mL each), Sampling Sheet B (5 pieces), batteries, dropper, manuals & case