Now Selling Draeger Gas Detection & Respiratory Products
Now Selling Draeger Gas Detection & Respiratory Products
Cart 0
Mercury Vapour 0.1/b, 0.05 - 2 mg/m3, (CH23101)
Draeger

Mercury Vapour 0.1/b, 0.05 - 2 mg/m3, (CH23101)

Regular price $104.00 Unit price per
Shipping calculated at checkout.

Mercury Vapour 0.1/b, 0.05 - 2 mg/m3, Part # CH23101, 10 Tests 

Application Range

Standard Measuring Range: 0.05 to 2 mg/m3

Number of Strokes n: 40 to 1

Time for Measurement: max. 10 min

Standard Deviation: ± 30 %

Color Change: pale yellow grey š pale orange

Ambient Operating Conditions

Temperature: 0 to 40 °C

Absolute Humidity: < 20 mg H2O / L

Reaction Principle

Hg + Cul š Cu-Hg-complex

Cross Sensitivity