Now Selling Draeger Gas Detection & Respiratory Products
Now Selling Draeger Gas Detection & Respiratory Products
Cart 0
Blackline G7X - Satellite Lone Worker Device
Blackline G7X - Satellite Lone Worker Device
Blackline G7X - Satellite Lone Worker Device
Blackline G7X - Satellite Lone Worker Device
Blackline G7X - Satellite Lone Worker Device
Blackline Safety

Blackline G7X - Satellite Lone Worker Device

Regular price $489.00 Unit price per
Shipping calculated at checkout.

Blackline G7X

True Last-Mile Safety Monitoring Technology

Meet G7x — the first and only comprehensive safety monitoring system with true last-mile connectivity to live monitoring personnel. Featuring an industrial-strength radio link, G7x communicates with the compact and portable G7 Bridge base station. Employees can work confidently over a mile away from the bridge knowing their safety is continuously being monitored in real-time. When your team needs the latest wireless gas monitor or remote lone worker technology, G7x and G7 Bridge work together to keep your teams covered, in even the most remote locations.

G7x defines a new level of lone worker monitoring technology. With seamless satellite connectivity, the G7x solution integrates the latest Internet of Things technology to keep your teams — and their safety — connected.

G7X delivers 3G communication for teams operating within cellular coverage in over 100 countries.

More than a gas monitor — connected safety monitoring, wherever you go

Blackline designed G7x to address every facet of your safety program. G7x gas monitors with lone worker monitoring leverage the G7 Bridge portable uplink base station to connect to available cellular and satellite networks.

Connectivity transitions effortlessly to satellite when working beyond 3G range to ensure constant safety monitoring. G7x communicates with G7 Bridge using an industrial-strength 900 MHz radio link up to 2 km away. G7 Bridge connects G7x employee-worn devices to the Blackline Safety Network via satellite or cellular networks.

Last-mile connectivity with instant alerting and text messaging

Even outside of 3G coverage, G7x automatically watches over team members and calls for help, even when the employee can’t. G7x connects workers with live monitoring teams 24/7 — should a gas leak, fall, no-motion or health incident occur, G7x equips responders with the situational awareness needed for optimized emergency responses. G7x with G7 Bridge can communicate with monitoring personnel using two-way text messaging delivering critical insights to workers, such as muster points during an evacuation.

Customizable gas detection

G7x tailors gas detection to specific work conditions with its exclusive modular design. Configurable cartridges make gas detection scalable to job requirements, with a selection of customizable gas sensors available. Choose a Standard (no gas), Single-gas or Quad-gas cartridge, then select from a range of gas sensors including hydrogen sulfide, oxygen, carbon monoxide and combustible gases, with more in development.

A modular design means G7x can scale from a single-gas monitor up to a four-gas detector. Blackline’s gas sensor-as-a-service replacement program helps teams maximize product uptime and ensure seamless gas detection and safety monitoring while minimizing maintenance costs.

Customize and configure your G7x gas detector cartridges and sensors.

Intuitive interface

G7x features a brilliant LCD screen — the graphical display is readable in direct sunlight and backlit for low light conditions. Simple displays and intuitive menus are easily navigable for straightforward use. The integrated SOS latch pull feature connects workers with monitoring personnel instantly, while the latch push button allows for easy check-ins and alert management.

Interface functionality is complemented by constant connectivity — when the G7c’s green SureSafe® light is on workers can be confident their safety is being monitored, wherever they may be. Vivid yellow lights accompanied by sound and vibration signal that G7c has a message for you, or is asking if you are OK. Red lights with escalated sound and vibration indicate assistance is needed, or that a yellow alarm has not been responded to.

Upcoming bump test and calibration reminders are easily accessible through G7x’s screen. Devices work with Blackline’s G7 Dock for simple bumps and calibrations. Test actions are performed using G7x’s LCD menu screen and provide straightforward dock functionality.

Blackline Live — web-based monitoring software

Seamless, comprehensive safety monitoring is empowered by Blackline Live, the web monitoring portal at the heart of the G7x solution. Employee-worn gas monitor devices can be easily configured for specific work conditions and environments. Emergency response protocols and device settings are configured in user accounts and provide monitoring personnel with the information necessary to manage an optimized emergency response.

Upload custom facility maps and floor plans to amplify response capabilities and direct responders directly to the employee’s location within the context of their surroundings. From the onset of an incident through to resolution, Blackline Live provides all the tools necessary to manage a world-class safety monitoring program, even in the most remote environments.

Wireless configuration

Constant connectivity to cell or satellite networks through G7 Bridge ensures that each G7x gas monitor is remotely configurable and that firmware updates are automatic for consistent and up-to-date operation. G7x shares current setup and configurations with employees at every start-up. From detecting gas leaks to monitoring lone workers and evacuating facilities, workers are covered — every safety incident and gas alert is communicated instantly to Blackline for storage and reporting.

Real-time compliance management and reporting

G7c delivers comprehensive gas detection and safety incident coverage for the diverse work environments faced by teams every day. G7c gas detectors wirelessly communicate compliance and usage data for automatic reporting to Blackline Live, alleviating the need for manual data collection from docks in the field. Every gas reading and safety incident is transmitted to live monitoring personnel in real time. Whether a worker calls for help using their SOS latch or a gas leak or safety event is detected, employees can rest easy knowing that details of their situation are being communicated to monitoring personnel, and that help is on the way.

Specifications

Standard G7 Safety Features

Fall detection and No-motion detection: Tri-axis accelerometer, tri-axis gyro, software processing, configurable sensitivity, configurable time for nomotion

SOS latch: Pull latch to trigger

SOS alert Silent SOS: Press and hold latch to trigger SOS alert

Low-battery: Configurable threshold

Worker check-in: Configurable timer (30 – 180 min, or off ), automatic check-in when driving.

Additional gas cartridge features

Under limit, Over limit, Time-weighted average (TWA), Short-term exposure limit (STEL), High gas alert, Low gas alert, Bump test and calibration notification, Bump test and calibration failure

Size & weight

G7 with Standard Cartridge Size: 64 mm x 124 mm x 27 mm (2.5” x 4.9” x 1.1”) Weight: 162 g (5.7 oz)

G7 with Single-gas Cartridge Size: 64 mm x 128 mm x 27 mm (2.5” x 5.0” x 1.1”) Weight: 167 g (5.9 oz)

G7 with Multi-gas diffusion Cartridge Size: 66 mm x 150 mm x 27 mm (2.5” x 5.9” x 1.1”) Weight: 192 g (6.8 oz)

G7 with Multi-gas pump Cartridge Size: 66 mm x 151 mm x 38.5 mm (2.6” x 5.95” x 1.52”) Weight: 238 g (8.4 oz)

User interface

168 by 144 pixel graphical, high contrast, liquid crystal display with front lighting, menu system driven by three-button keypad, power button (on/off ), check-in button (check-in/silent SOS), SOS latch (send emergency alert)

Multi-language support: Yes, EN, FR, ES, DE, IT, NL, PT

User notification

Green SureSafe® light: Blinking (powered), continuous (connected)

Yellow top and front lights: Yellow pending alarm and yellow warning alarm

Red top and front lights: Red alert communicated

Blue LiveResponse™ top and front lights: Confirmation that a monitoring team has acknowledged the alert

Alarm Indicators: Speaker, LED lights and vibration motor

Speaker sound pressure level: ~95 dB @ 30 cm (~95 dB @ 11.8”)

G7x Wireless Radio

Works with G7 Bridge satellite base station Radio: 902.0 – 928.0 MHz, 1 Watt AS/NZ Radio: 915.0-928.0 MHz Antenna: Internal Radio link range: 2 km (1.25 mi)

 

Location technology

GPS Radio: 48-channel high sensitivity

Assisted-GPS: Yes (G7c model only)

GPS Accuracy: ~5 m (16 ft) Outdoors

Indoor location technology: Blackline Safety location beacons

Location update frequency: G7c 5 min, G7x 15 min defaults

Power & battery

Rechargeable Li-ion battery: 1100 mAh Li-ion

Battery Life: 18 hours at 20°C (68°F) under normal usage

Charge time: 4 hours

Environmental

Storage temperature: -30°C to 60°C (-22°F to 140°F)

Operating temperature: -20°C to 55°C (-4°F to 131°F)

Charging temperature: 0°C to 45°C (32°F to 113°F)

Ingress Protection: Designed to meet IP67

Approvals

G7x: SAR, RoHS, RCM

FCC ID: W77G7X

IC: 8255A-G7X

Canada & USA: Class I Division 1 Group A,B,C,D T4; Class I Zone 0 AEx da ia IIC T4; Ex da ia IIC T4 Ga

IECEx: Ex ib IIC T4 Gb

LEL: CSA C22.2 No.152; ISA 12.13.01

LEL Pump Cartridge: CSA C22.2 No.152; 0°C ≤ Ta ≤ 40°C; ANSI/ISA-12.13.01; -10°C ≤ Ta ≤ 40°C

Warranty

G7: two years limited warranty

Cartridges: lifetime with service plan

Blackline Complete: three year operating lease with three year warranty

 

Gas Sensors

Ammonia (NH3) -  Type: Electrochemical, Model: Citytech, Sensoric NH3 3E 100 SE, Range: 0–100 ppm Resolution: 0.1 ppm

High-range ammonia (NH3) - Type: Electrochemical, Model: Sensoric NH3 E3 500 SE, Range: 0–500 ppm, Resolution: 1 ppm

Carbon monoxide (CO) - Type: Electrochemical Citytech, 4CF+ CiTiceL, Range: 0–500 ppm, Resolution: 1 ppm

High-range carbon monoxide (CO) - Type: Electrochemical Citytech 4CM, Range: 0–2000 ppm, Resolution: 5 ppm

Hydrogen resistant carbon monoxide (CO-H) - Type: Electrochemical Citytech 2CF3, Range: 0–500 ppm, Resolution: 1 ppm

Carbon dioxide (CO2) - Type: NDIR Gas Sensing Solutions, MinIR, Range: 0–50,000 ppm, Resolution: 50 ppm

Chlorine (Cl2) - Type: Electrochemical Citytech, Sensoric Cl2 3E 50, Range: 0–20 ppm, Resolution: 0.1 ppm

Chlorine dioxide (ClO2) - Type: Electrochemical Sensoric ClO2 3E 1 O, Range: 0–2 ppm, Resolution: 0.01 ppm

COSH - Type: Electrochemical Citytech, 4COSH Dual Gas CO/ H2S Sensor, Range: 0–500 ppm CO, 0–100 ppm H2S, Resolution: 1 ppm CO, 0.1 ppm H2S

Hydrogen cyanide (HCN) - Type: Electrochemical Sensoric HCN 3E 30 F, Range: 0–30 ppm, Resolution: 0.1 ppm

Hydrogen sulfide (H2S) - Type: Electrochemical City Technology, 4HS+ Hydrogen Sulfide CiTiceL, Range: 0–100 ppm, Resolution: 0.1 ppm

High-range hydrogen sulfide (H2S) - Type: Electrochemical City Technology, 4HS+ Hydrogen Sulfide CiTiceL, Range: 0-500 ppm, Resolution: 0.5 ppm

LEL-infrared (LEL-IR) - Type: NDIR MIPEX, 02-X-X-X.1, Range:  0–100% LEL, Resolution: 1% LEL

Nitrogen dioxide (NO2) - Type: Electrochemical City Technology, 4ND, Range: 0–50 ppm, Resolution: 0.1 ppm

Oxygen (O2) Pumped - Type: electrochemical City Technology, 4OxLL Longlife Oxygen CiTiceL, Range: 0–25% vol, Resolution: 0.1% vol

Ozone (O3) - Type: Electrochemical Sensoric O3 3E 1, Range:  0–1 ppm, Resolution: 0.01 ppm

Photoionization (PID) ppm - Type: PID Ion Science, MiniPID 2, Range: 0–4,000 ppm*, Resolution: Dynamic resolution*

Photoionization (PID) ppb - Type: PID Ion Science, MiniPID 2, Range: 0-10,000 ppb*, Resolution: Dynamic resolution*

Sulfur dioxide (SO2) - Type: Electrochemical City Technology, 4S Rev. 2 Sulfur Dioxide CiTiceL, Range:  0–100 ppm, Resolution: 0.1 ppm


Blackline Bridge Required for Operation of G7X

G7 Bridge

The G7x system includes the G7x user-worn device and G7 Bridge portable satellite and cellular base station. Leveraging 3G and Iridium satellite networks, connectivity seamlessly transitions to satellite when cellular becomes unavailable, providing true last-mile monitoring. Up to five G7x devices connect with G7 Bridge through an industrial-quality 900 MHz radio link from up to 2 km away. G7 Bridge can mass-notify employees of the need to evacuate and connect workers to monitoring personnel via two-way messaging. G7 Bridge is self-powered and portable, allowing users to quickly move it from one vehicle to another. It has your teams' back — at all times, no matter their location.

Size & Weight

Size: 73 mm x 107 mm x 141 mm (2.87”x 4.21”x 5.55”) Measurements do not include mount

Weight: 540 g (19.04 oz)

Wireless Communication

Radio: UMTS 800/850/900/1900/2100; Quad-band GSM/GPRS 850, 900, 1800, 1900; Iridium Satellite (1621 MHz); ISM band radio (915 MHz)

900 MHz Radio: Americas: 902 – 928 MHz Australian/ New Zealand: 916 – 927 MHz, 1 Watt

900 MHz Radio Link Range

General use: up to 2 km

Hilltop to hilltop: 10+ km Terrain, foliage, and buildings will affect overall 900 MHz radio link range

Power & Battery

Rechargeable Li-ion battery: 6800 mAh capacity

Battery Life: 50 hours @ 20°C (68°F); 44 hours @ -20°C (-4°F); 14 hours @ -40°C (-40°F); It is recommended that the hard wire kit is used anytime below -20°C

Charging connector: Micro USB

Antenna: Internal