The premium, highly accurate dipperLog TOUGH+ with titanium body and transducer is suitable for use by environmental technicians and other groundwater professionals in the most caustic and hazardous of environments. The dipperLog TOUGH+ is a reliable, cost effective solution for long and short term monitoring of groundwater levels and temperature in wells where contamination is a concern.

Features & Advantages

  • Memory – 128,000 data sets (depth and temperature of water)
  • Download Speed – 128,000 data sets in 6 minutes (21,333.33 Sets/min)
  • Battery – up to 15 years or 5,000,000 readings (depending on usage)
  • Calibration Certificate with each logger
  • Machined, Titanium body and transducer
  • Able to convert deployment options easily in the field

Specifications

Performance
# of Data Points 128,000
Download Speed 21,333.33 Data Sets/min (128,000 readings downloads in 6 minutes)
Water Level Accuracy (Typical) +/- 0.05%FS (0°C to 50°C)
Temperature Accuracy (Typical) +/- 0.05°C 
(Temperature Sensor Meets 
ASTM E1112 and ISO 80601-2-56. 
NIST Traceability)
Operating Features
Pressure Ranges 10m/30ft (14PSI), 30m/100ft (43PSI), 60m/200ft (85PSI), 120m/400ft (171PSI)
Overpressure Rating 2X Factory Calibrated Range
Operating Temperature -20°C to 80°C (-5°F to 175°F)
Pressure Resolution %FS 0.001
Expected Battery Life (Depending on Usage) Up to 5,000,000 Readings (
Up to 15 Years)
Warranty 3 Years
Physical Characteristics
Wetted Material Titanium, Delrin, Teflon
O-Ring (Primary) Teflon
O-Ring (Backup) Viton
Transducer Titanium Piezoresistive Silicon
Length 145mm / 5.7”
Diameter 22mm / 0.87”
Weight 150g
Deployment Options
Suspended
Direct Read
Reel
Note: In "Log Time" mode the dipperLog increases the readings from 1 second by an additional 1 second for 255 readings. The final reading interval is 4 min. and 14 sec. and the logger then stops logging. This mode logs for a total of 9 hours before stopping.
Barometric Compensation The first reading can be used for all readings unless a barLog is used. Automatic compensation when using a designated barLog. Manual compensation in Excel.
Direct Read Cable 1/8" Polyurethane